Q: How to monitor (digital) sensor communication
A: To check or monitor digital sensor communication, enable the debug mode when connected to the data logger with YdocTerminal.
Enter the following command sequence:
<Cntrl>a <Shift>d <Cntrl>d
T: After debugging, the same command sequence disables debug mode.
T: Real-time debugging ASCII sensors is not possible.
Enable raw-value saving to the SD card. After testing download the data file and check results.
Option [6], Log raw data string.
Change from [0], “Off” to [1], “On”.